Troubleshooting
Operating Instructions 513/533 - 01.0 - 09/2023 115
M-309 Seam pattern
beyond the
sewing area
The system discovers during
the calculation that the seam
pattern is outside of the sewing
area.
Press the RESET button and
confirm that the size of the
seam pattern is within the
area set in the parameters
K056, K057, K058, and K059.
M-310 Stitch length
outside of the
normal range
During the calculation, the stitch
length is outside of the normal
range.
Press the RESET button and
confirm the seam pattern and
the X/Y scale rate.
M-311 Seam
pattern data
communication
abnormal
This error occurs when the
control panel transmits seam
pattern data to the control.
Check the seam pattern and
the cable connection between
the control panel and the
control.
M-312 Normal seam
pattern lock
abnormal
The control panel is unable to
read the normal seam pattern
lock data from the EEPROM.
Press the RESET button to
call up the system menu and
restore the default setting.
M-313 Current seam
pattern
parameters
abnormal
The control panel is unable to
read the seam pattern
parameter data from the
EEPROM.
Press the RESET button to
call up the system menu and
restore the default setting.
M-314 Parameter
setting above
normal range
The value set for the parameter
exceeds the normal range.
Press the RESET button and
change the set value.
M-315 Counter
abnormal
The control panel is unable to
read the counter data from the
EEPROM.
Press the RESET button to
call up the system menu and
restore the default setting.
M-316 Counter
exhausted
The counter has reached the
upper limit after sewing.
Press the RESET button.
Error Description Possible cause Troubleshooting

Table of Contents