Programming
58 Operating Instructions 513/533 - 01.0 - 09/2023
U043 Brightness of LED on machine head 0 to 10
0 = off
the higher the value,
the brighter the LED
-8
U046 No thread cutting allowed 0 = normal
1 = no thread cutting
-0
U049 Adjust winding speed 800 to 2000 rpm 1600
U055 Start bartack not allowed for sewing on
buttons
0 = start bartack
1 = no start bartack
-0
U063 Method for adjusting the X/Y scaling 0 = based on percentage
1 = based on size
%/mm 0
U135 Sewing foot movement prior to sewing 0 = positioned at seam
beginning
1 = positioned at origin
-0
U200 Language Setting the language - Simpli-
fied
U212 Air valve separate presser foot
lowering
0 = simultaneous
lowering
1 = lower left presser
foot first, then the right
presser foot
2 = lower right presser
foot first, then the left
presser foot
-0
U213 Air valve separate presser foot lifting 0 = simultaneous lifting
1 = lift left sewing foot
first, then the right
presser foot
2 = lift right sewing foot
first, then the left presser
foot
-0
U214 Availability of the top feed foot 0 = prohibited
1 = available
-1
No. Function Value range Unit Default