Programming Commander DELTA
130 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
5.8.7.1 Setting the Light barrier parameters
The light barrier detects the beginning and the end of the material.
After a signal was detected, sewing can continue automatically
with the specifically set parameters.
Icon Menu item Setting
Distance
Distance from the detection of the
signal to the end of the material.
This distance signifies the path from the
needle to the light barrier. The path is
specified in millimeters and used by the
machine to independently calculate the
number of stitches.
Value range
0 - 255
Signal detection at seam begin
The signal scan of the light barrier is per-
formed at the beginning of the seam. If
the function is activated, the light barrier
must detect a signal to allow the machine
to sew. If the function is inactive, sewing
can take place without signal detection.
Value range
On/Off
Signal detection at seam end
The signal scan of the light barrier is
performed at the end of the seam. If the
function is active, the machine will
continue to sew with the specifically
set parameters following the signal
detection. If the function is inactive,
nothing will happen.
Value range
On/Off
Seams
Input of the number of signal detections
after which the machine is supposed to
continue with the specifically set
parameters.
Value range
1 - 255
Filter stitches
Loosely woven fabric with stitches may
cause the light barrier to wrongly detect a
signal. To prevent this from happening,
you enter the number of filter stitches.
This number represents the minimum
number of stitches with signal detection
following the 1
st
detection of the signal.
Value range
0 - 255