Troubleshooting
174 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
1004 Error Incorrect sewing motor
direction of rotation
Replace encoder
Check motor plug assignment and
change it if necessary
Check wiring in machine distributor and
change it, if necessary
Test motor phases and check for correct
value
1005 Error Motor blocked Check for stiff movement
Replace encoder
Replace sewing motor
1006 Error Maximum speed exceeded Replace encoder
Perform reset
Check class (t 51 04)
1007 Error Error in the reference run Replace encoder
Check for stiff movement
1008 Error Sewing motor encoder error Replace encoder
1010 Error External synchronizer plug
(Sub-D, 9-pin) not connected
Connect cable of external synchronizer
to control, make sure that interface
(Sync) is correct
Only recommended for machines with
transmission!
1011 Error Encoder Z pulse missing Switch off the control, use handwheel
to turn, and switch on the control again
If error is not corrected, check encoder
1012 Error Synchronizer fault Replace synchronizer
1054 Error Internal short circuit Replace control
1055 Error Sewing motor overload Check for stiff movement
Replace encoder
Replace sewing motor
1060 Error Sewing motor overload /
overvoltage /overcurrent
Check selection of class
Replace control
Replace motor
Replace encoder
1061 Error Sewing motor overload /
overvoltage /overcurrent
Check selection of class
Replace control
Replace motor
Replace encoder
Code Type Possible cause Remedial action