EasyManua.ls Logo

DURKOPP ADLER M-Type Delta D867 - Page 177

DURKOPP ADLER M-Type Delta D867
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 175
1120 Error Sewing motor Init fault Perform a software update
Check selection of class
1121 Error Sewing motor watchdog Perform a software update
Check selection of class
1203 Error Position not reached (during
thread cutting, reversal, etc.)
Check the controller settings and
change them if necessary (e.g. thread
trimmer setting, belt tension, etc.)
Check position thread lever at top
dead center
1302 Error Failure with sewing motor
current
Check Service Stop
Check for stiff movement
Replace encoder
Replace motor
1330 Error No response from sewing
motor
Perform a software update
Replace control
2101 Error Stepper motor X30 reference
run timeout
Check reference sensor
2105 Error Stepper motor card X30
blockage
Check for stiff movement
2121 Error Stepper motor card X30
encoder plug (Sub-D, 9-pin)
not connected
Connect encoder cable to the control,
use the correct interface
2122 Error Stepper motor card X30
flywheel position not found
Check stepper motor 1 for stiff
movement
2130 Error Stepper motor card X30 not
responding
Perform a software update
Replace control
2131 Error Stepper motor card X30
parameter init
Perform a software update
Check selection of class
2152 Error Stepper motor card X30
overcurrent
Check for stiff movement
2171 Error Stepper motor card X30
Watchdog (Stitch length)
Perform a software update
Check selection of class
2172 Error Stepper motor card X30 motor
overload / overvoltage /
overcurrent (Stitch length)
Check selection of class
Replace control
Replace encoder
Replace stepper motor
Code Type Possible cause Remedial action