EasyManua.ls Logo

DURKOPP ADLER M-Type Delta D867 - Page 181

DURKOPP ADLER M-Type Delta D867
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 179
2288 Error Stepper motor card X40
Reference drive failure
(Foot lifting)
Check for stiff movement
Replace encoder
Replace motor
2301 Error Stepper motor card X50
Reference drive failure
(Stitch length)
Check reference sensor
2305 Error Stepper motor card X50
stepper motor blockage
Check for stiff movement
2321 Error Stepper motor card X50
encoder plug (Sub-D, 9-pin)
not connected
Connect encoder cable to the control,
use the correct interface
2322 Error Stepper motor card X50
flywheel position not found
Check stepper motor 1 for stiff
movement
2330 Error Stepper motor card X50 not
responding
Perform a software update
Replace control
2331 Error Stepper motor card X50
parameter init error
Perform a software update
Check selection of class
2352 Error Stepper motor card X50
overcurrent
Check for stiff movement
2371 Error Stepper motor card X50
Watchdog (sewing foot lift)
Perform a software update
Check selection of class
2372 Error Stepper motor card X50 motor
overload / overvoltage /
overcurrent (Foot stroke)
Check selection of class
Replace control
Replace encoder
Replace stepper motor
2373 Error Stepper motor card X50
Sewing motor encoder not
connected(Foot stroke)
Replace control
2374 Error Stepper motor card X50
Sewing motor encoder not init
(Foot stroke)
Perform a software update
Check selection of class
2375 Error Stepper motor card X50 Init
Position not found
(Foot stroke)
Check for stiff movement
Replace encoder
Replace motor
2376 Error Stepper motor card X50 not
Enabled (Foot stroke)
Replace control
Code Type Possible cause Remedial action