Troubleshooting
178 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
2274 Error Stepper motor card X40
Sewing motor encoder not init
(Foot lifting)
Perform a software update
Check selection of class
2275 Error Stepper motor card X40 Init
Position not found (Foot lifting)
Check for stiff movement
Replace encoder
Replace motor
2276 Error Stepper motor card X40 not
Enabled (Foot lifting)
Replace control
2277 Error Stepper motor card X40 I²t
(Foot lifting)
Check for stiff movement
Replace encoder
Replace motor
2278 Error Stepper motor card X40
Encoder failure (Foot lifting)
Replace encoder
2279 Error Stepper motor card X40
Current sensor failure
(Foot lifting)
Replace control
2280 Error Stepper motor card X40
Incorrect stepper motor
direction of rotation
(Foot lifting)
Replace encoder
Check if plugs have been mixed up
Check the wiring in the machine
distributor and change it if necessary
2281 Error Stepper motor card X40
Reference drive failure
(Foot lifting)
Check for stiff movement
Replace encoder
Replace motor
2283 Error Stepper motor card X40
overcurrent (Foot lifting)
Replace control
2284 Error Stepper motor card X40
parameter init (Foot lifting)
Perform a software update
Check selection of class
2285 Error Stepper motor card X40
insulation error (Foot lifting)
Check motor phase and PE for low-
impedance connection
Replace encoder
Replace sewing motor
2287 Error Stepper motor card X40
transport interval failure
(Foot lifting)
Perform a software update
Check selection of class
Code Type Possible cause Remedial action