Troubleshooting
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 177
2187 Error Stepper motor card X30
transport interval failure
(Stitch length)
Perform a software update
Check selection of class
2188 Error Stepper motor card X30
Reference drive failure
(Stitch length)
Check for stiff movement
Replace encoder
Replace motor
2201 Error Stepper motor X40 reference
run timeout
Check reference sensor
2205 Error Stepper motor card X40
stepper motor blockage
Check for stiff movement
2221 Error Stepper motor card X40
encoder plug (Sub-D, 9-pin)
not connected
Connect encoder cable to the control,
use the correct interface
2222 Error Stepper motor card X40
flywheel position not found
Check stepper motor 1 for stiff
movement
2230 Error Stepper motor card X40 not
responding
Perform a software update
Replace control
2231 Error Stepper motor card X40
parameter init error
Perform a software update
Check selection of class
2252 Error Stepper motor card X40
overcurrent
Check for stiff movement
2271 Error Stepper motor card X40
Watchdog (sewing foot lift)
Perform a software update
Check selection of class
2272 Error Stepper motor card X40 motor
overload / overvoltage /
overcurrent (Foot lifting)
Check selection of class
Replace control
Replace encoder
Replace stepper motor
2273 Error Stepper motor card X40
Sewing motor encoder not
connected (Foot lifting)
Replace control
Code Type Possible cause Remedial action