Troubleshooting
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 181
2405 Error Stepper motor card X60
stepper motor blockage
(Edge guide)
Check for stiff movement
2421 Error Stepper motor card X60
encoder plug (Sub-D, 9-pin)
not connected
Connect encoder cable to the control,
use the correct interface
2422 Error Stepper motor card X60
flywheel position not found
Check stepper motor 1 for stiff
movement
2430 Error Stepper motor card X60 not
responding
Perform a software update
Replace control
2431 Error Stepper motor card X60
parameter init error
Perform a software update
Check selection of class
2471 Error Stepper motor card X60
Watchdog (Edge guide)
Perform a software update
Check selection of class
2472 Error Stepper motor card X60 motor
overload / overvoltage /
overcurrent (Edge guide)
Check selection of class
Replace control
Replace encoder
Replace stepper motor
2473 Error Stepper motor card X60
Sewing motor encoder not
connected(Edge guide)
Replace control
2474 Error Stepper motor card X60
Sewing motor encoder not init
(Edge guide)
Perform a software update
Check selection of class
2475 Error Stepper motor card X60 Init
Position not found
(Edge guide)
Check for stiff movement
Replace encoder
Replace motor
2476 Error Stepper motor card X60 not
Enabled (Edge guide)
Replace control
2477 Error Stepper motor card X60
Overload (Edge guide)
Check for stiff movement
Replace encoder
Replace motor
2478 Error Stepper motor card X60
Encoder failure (Edge guide)
Replace encoder
Code Type Possible cause Remedial action