Troubleshooting
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 181
2405 Error Stepper motor card X60
stepper motor blockage
(Edge guide)
• Check for stiff movement
2421 Error Stepper motor card X60
encoder plug (Sub-D, 9-pin)
not connected
• Connect encoder cable to the control,
use the correct interface
2422 Error Stepper motor card X60
flywheel position not found
• Check stepper motor 1 for stiff
movement
2430 Error Stepper motor card X60 not
responding
• Perform a software update
• Replace control
2431 Error Stepper motor card X60
parameter init error
• Perform a software update
• Check selection of class
2471 Error Stepper motor card X60
Watchdog (Edge guide)
• Perform a software update
• Check selection of class
2472 Error Stepper motor card X60 motor
overload / overvoltage /
overcurrent (Edge guide)
• Check selection of class
• Replace control
• Replace encoder
• Replace stepper motor
2473 Error Stepper motor card X60
Sewing motor encoder not
connected(Edge guide)
• Replace control
2474 Error Stepper motor card X60
Sewing motor encoder not init
(Edge guide)
• Perform a software update
• Check selection of class
2475 Error Stepper motor card X60 Init
Position not found
(Edge guide)
• Check for stiff movement
• Replace encoder
• Replace motor
2476 Error Stepper motor card X60 not
Enabled (Edge guide)
• Replace control
2477 Error Stepper motor card X60
Overload (Edge guide)
• Check for stiff movement
• Replace encoder
• Replace motor
2478 Error Stepper motor card X60
Encoder failure (Edge guide)
• Replace encoder
Code Type Possible cause Remedial action