Troubleshooting
182 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
2479 Error Stepper motor card X60
Current sensor failure
(Edge guide)
Replace control
2480 Error Stepper motor card X60
Incorrect stepper motor
direction of rotation
(Edge guide)
Replace encoder
Check if plugs have been mixed up
Check the wiring in the machine
distributor and change it if necessary
2481 Error Stepper motor card X60
Reference drive failure
(Edge guide)
Check for stiff movement
Replace encoder
Replace motor
2483 Error Stepper motor card X60
overcurrent (Edge guide)
Replace control
2484 Error Stepper motor card X60
parameter init (Edge guide)
Perform a software update
Check selection of class
2485 Error Stepper motor card X60
insulation error (Edge guide)
Check motor phase and PE for low-
impedance connection
Replace encoder
Replace sewing motor
2487 Error Stepper motor card X60
transport interval failure
(Edge guide)
Perform a software update
Check selection of class
2488 Error Stepper motor card X60
Reference drive failure
(Edge guide)
Check for stiff movement
Replace encoder
Replace motor
2501 Error Stepper motor card X70
reference run timeout
(upper Puller)
Check reference sensor
2505 Error Stepper motor card X70
stepper motor blockage
(upper Puller)
Check for stiff movement