Troubleshooting
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 185
2622 Error Stepper motor card X80
flywheel position not found
(bottom puller)
• Check stepper motor 6 for stiff
movement
2630 Error Stepper motor card X80 not
responding (bottom puller)
• Perform a software update
• Replace control
2631 Error Stepper motor card X80 init
failure (bottom puller)
• Perform a software update
• Check selection of class
2671 Error Stepper motor card X80
Watchdog (bottom puller)
• Perform a software update
• Check selection of class
2672 Error Stepper motor card X80 motor
overload / overvoltage /
overcurrent (bottom puller)
• Check selection of class
• Replace control
• Replace encoder
• Replace stepper motor
2673 Error Stepper motor card X80
Sewing motor encoder not
connected (bottom puller)
• Replace control
2674 Error Stepper motor card X80
Sewing motor encoder not init
(bottom puller)
• Perform a software update
• Check selection of class
2675 Error Stepper motor card X80 Init
Position not found
(bottom puller)
• Check for stiff movement
• Replace encoder
• Replace motor
2676 Error Stepper motor card X80 not
Enabled (bottom puller)
• Replace control
2677 Error Stepper motor card X80 I²t
(bottom puller)
• Check for stiff movement
• Replace encoder
• Replace motor
2678 Error Stepper motor card X80
Encoder failure (bottom puller)
• Replace encoder
2679 Error Stepper motor card X80
Current sensor failure
(bottom puller)
• Replace control
Code Type Possible cause Remedial action