Troubleshooting
186 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
2680 Error Stepper motor card X80
Incorrect stepper motor
direction of rotation
(bottom puller)
Replace encoder
Check if plugs have been mixed up
Check the wiring in the machine
distributor and change it if necessary
2681 Error Stepper motor card X80
Reference drive failure
(bottom puller)
Check for stiff movement
Replace encoder
Replace motor
2683 Error Stepper motor card X80
overcurrent (bottom puller)
Replace control
2684 Error Stepper motor card X80
parameter init (bottom puller)
Perform a software update
Check selection of class
2685 Error Stepper motor card X80
insulation error (bottom puller)
Check motor phase and PE for low-
impedance connection
Replace encoder
Replace sewing motor
2687 Error Stepper motor card X80
transport interval failure
(bottom puller)
Perform a software update
Check selection of class
2688 Error Stepper motor card X80
Reference drive failure
(bottom puller)
Check for stiff movement
Replace encoder
Replace motor
2901 Error General Reference Timeout of
the stepper motors
Check the reference sensors
3010 Error U100 V start-up error Disconnect the stepper motor plugs;
if error persists, replace control
3011 Error U100 V short circuit Disconnect motor plug; replace control
if error is not corrected: Replace control
3012 Error U100 V (I²T) overload One or several stepper motors defective
3020 Error U24 V start-up error Disconnect magnet plug; replace control
if error is not corrected: Replace control
Code Type Possible cause Remedial action