EasyManua.ls Logo

DURKOPP ADLER M-Type Delta D867 - Page 189

DURKOPP ADLER M-Type Delta D867
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 187
3021 Error U24 V short circuit Disconnect magnet plug; replace control
if error is not corrected: Replace control
3022 Error U24 V (I²T) overload One or several magnets defective
3030 Error Motor phase failure Replace control
3104 Warning Pedal is not in position 0 When switching the control on, take your
foot off the pedal
3109 Warning Operation lock Check tilt sensor on machine
3110 Information Right thread tension magnet is
not connected
Check the connection of right thread
tension magnet
3111 Information Left thread tension magnet is
not connected
Check the connection of left thread
tension magnet
3150 Information Maintenance necessary For information on lubricating the
machine, see the service instructions for
the machine
3217 Information RFW right Bobbin is empty
Insert a new bobbin
3223 Information Skip stitch detection -
3224 Information Bobbin rotation monitor The bobbin is not rotating
Check the bobbin, advance the initial
thread
3225 Information SSD sensor is soiled Use compressed air or a soft cotton
cloth to clean the sensor
3354 Information Failure in thread trimmer
process
Perform a software update
3383 Information Failure in with the motor
referencing process
Check motor
Perform a software update
4201 Warning Failure SD-Card Insert SD card
Replace control
Code Type Possible cause Remedial action