Programming Commander DELTA
86 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
5.6.3.1 Setting the Bobbin monitor mode parameters
The amount of remaining thread on the bobbin can be monitored
optically or by software using this setting.
Menu item Setting option 1 Setting option 2
Off
Monitor
Monitor mode can only be used if
the additional equipment of the
remaining thread monitor is present
on the machine.
Monitor mode allows for optical
monitoring of the bobbin.
Sewing stop
Sewing stops and a notice is shown
on the display when the bobbin is
detected to be nearly empty. If the
parameter is not activated, only the
LEDs on the machine arm give a
warning if the bobbin is empty.
Value range
On/Off
Sewing foot lower position Value range
On/Off
t Clean
Duration for which the lens is blown
clear with compressed air.
The process takes place as the
thread is cut.
Value range
0000 – 5000 [ms]