Programming Commander DELTA
Operating Instructions M-TYPE DELTA - 01.0 - 08/2019 93
Setting options Sewing foot stroke
Menu item Setting 1 Setting 2
linear Sewing foot stroke
Value range 00 – 09 [mm]
Maximum sewing foot 
stroke reached at the upper 
material thickness limit.
Min. Material 
thickness
Value range 00.0 – 10.0 [mm]
Material thickness at which 
the increase in sewing foot 
stroke should start.
Max. Material 
thickness
Value range 00.0 – 10.0 [mm]
Material thickness up to 
which the increase in 
sewing foot stroke should 
occur.
2.OnOff Min. Material 
thickness
Value range 00.0 – 10.0 [mm]
Material thickness from 
which the 2
nd
sewing foot 
stroke should be used.
2.On Min. Material 
thickness
Value range 00.0 – 10.0 [mm]
Material thickness from 
which the 2
nd
sewing foot 
stroke should be used.