EasyManua.ls Logo

DURKOPP ADLER M-Type Delta D867 - Page 96

DURKOPP ADLER M-Type Delta D867
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming Commander DELTA
94 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Setting options Stitch length
Menu item Setting 1 Setting 2
linear Stitch length
Value range -50 50 [%]
Maximum stitch length
variation reached at the
upper material thickness
limit.
Min. Material
thickness
Value range 00.0 10.0 [mm]
Material thickness at which
the increase/reduction of
stitch length should start.
Max. Material
thickness
Value range 00.0 10.0 [mm]
Material thickness up to
which the increase/
reduction of stitch length
should occur.
2.OnOff Min. Material
thickness
Value range 00.0 10.0 [mm]
Material thickness from
which the 2
nd
stitch length
should be used.
2.On Min. Material
thickness
Value range 00.0 10.0 [mm]
Material thickness from
which the 2
nd
stitch length
should be used.