EasyManua.ls Logo

DURKOPP ADLER M-Type Delta D867 - Page 98

DURKOPP ADLER M-Type Delta D867
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming Commander DELTA
96 Operating Instructions M-TYPE DELTA - 01.0 - 08/2019
Setting options Max. sewing speed
5.6.3.4 Setting the Outputs (Output) parameter
This parameter provides virtual outputs that can be assigned
customer-specific functions. They can be used when customer-
specific applications require a signal from the control of the
machine.
These parameters cannot be used unless the virtual outputs
have been assigned to a physical output at the Technician level.
This requires that the parameter Additional I/O Configu-
ration be configured at the Technician level; for more details,
refer to the explanation in the Service Instructions.
Menu item Setting 1 Setting 2
linear Max.
sewing speed
Value range 0000 4000
Maximum speed reached
at the upper material
thickness limit.
Min. Material
thickness
Value range 00.0 10.0 [mm]
Material thickness at which
the increase in sewing
speed should start.
Max. Material
thickness
Value range 00.0 10.0 [mm]
Material thickness up to
which the increase in
sewing speed should
occur.

Table of Contents

Other manuals for DURKOPP ADLER M-Type Delta D867

Related product manuals