The flashing code is displayed by flashing of the control light over a different length
of time. There is a difference between the „long“ and „short“ signals. There is a longer
break between the short and long blocks of signals.
Duration of the short flashing signal: 400ms
Duration of the long flashing signal: 800ms
Duration of the break: 2000ms
If the error query switch is again in position 0, the warning light, which indicated the
fault, will come on again (will flash or will be lit up continuously). This will be as long
as the fault or problem is eliminated.
A
In order to check if no several faults have occurred at the same time, the diagnostic
switch has to be turned on again.
If the same flashing code can be seen again as before, then there is no additional
fault.
Repeat this process until the first error message appears again.
Record all the faults displayed.
m
Report the displayed fault code to the customer service of the paver finisher and they
will discuss with you the steps to be taken.