F 6.0 4
F_6.0_01_GB.fm 4-8
Suction/return flow hydraulic filter (2)
Change the filter by the intervals speci-
fied or when the maintenance indicator
(A) at a hydraulic oil temperature of 80°C
comes to the red mark.
A
The temperature of the hydraulic oil can
be read on the hydraulic temperature in-
dicator (O) at the operating position.
m
When changing the hydraulic oil also
change the filter.
- Remove the lid fastening screws (B)
and remove the lid.
- Disassemble the withdrawn unit into
the following parts:
- lid (C)
- separating plate (D)
- filter (E)
- dirt collection cage (F)
- Clean the filter case, the lid, the sepa-
rating plate and the dirt collection
cage.
- Check and replace the O-rings (G)
when required.
- Wet the seal surfaces and the O-ring
with clean fuel.
Hydtank_V2.eps/Montage2.eps/Hydtank_V2a.eps
G
F E
D C
A
B
H
I