D 4.6 6
D_4.6_01_GB.fm 6-38
After starting
To increase the engine speed:
- Set the RPM regulator (1) to medium
speed.
- Switch the drive lever (2) to position 1
(slightly moving it from the central po-
sition).
m
Let the paver finisher warm up for ca. 5
minutes if the engine is cold.
Indicator lamps
The following indicator lamps must be
observed under all circumstances:
For further possible faults, refer to the
operating instructions for the engine.
Battery charge indicator (1).
Must go out after starting when the en-
gine revs up.
m
Briefly rev up the engine when the lamp
does not go out or lights up during oper-
ation.
Switch off the engine and determine the cause for the malfunction if the lamp does
not go out.
For further possible malfunctions, refer to the section „Malfunctions”.
Oil pressure indicator lamp for the
traction drive (2)
- Must go out after starting.
m
If the lamp does not go out: Do not
switch on the traction drive! Otherwise,
the entire hydraulic system could be
damaged.
Element2_konv_Kette_635.bmp/Element3a_konv_Kette_635.bmp
1
2
Leuchtmodul_KONV_Kette_635.bmp
1
Leuchtmodul_KONV_Kette_635.bmp
2