F 8.1 3
F_8.1_01_GB.fm 3-20
No.
Interval
Points of maintenance Remark
10
50
100
250
1000
5000
20000
as required
2
q
- Generator
Checking of operation of the insu-
lation monitoring of electric equip-
ment
Also see
the opera-
tion manu-
al of the
screed
q
- Generator
Visual checking for pollution or
damage
- Check the cooling air openings
for pollution or clogging, clean as
required.
(o)
q
- Generator
Check the ball bearings "by lis-
tening" and replace them as re-
quired.
(o)
qq
- Generator
Replacement of ball bearings
(o)
q
- Generator
Check the drive belts (o) for inju-
ry and replace them as required.
(o)
q
- Generator
Drive belts (o) - check tightness
and adjust as required.
(o)
Only on
version with
V-belt!
q
- Generator
Replacement of drive belts (o)
(o)