26. Diameter of Plate and Y-Positions
5021, 300, 0, 0, 0, ......
300 Diameter of Plate
0 D1, Center deflector
0 D2
27. “Other” Physicals
5022,0, 0, 0, 45, 97, 195, 386,
0 Plate Type: 0=Standard 1=Split Plate
0 NA
0 NA
45 Height ONE
97 Height TWO
195 Height THREE
386 Height FOUR
28. Station and Lane Information
5023,1,3,0, 23.800, 31.200, 31.200, 0.200, 0.000,1,1
1 3 0 Legacy
23.800 Min Station
31.200 Max Station
31.200 Previous Station
0.200 Station Step
0.000,1,1 Legacy
29. Test Setup Options
5024,0,1,1,1,1,1, 0, 0.0, 0, 0.0,0,0,0, 60
0 Station Prompt
1 Temperature Prompt(s)
1 Condition Prompt
1 Reject Prompt
1 Decrease Check
1 Roll Off Check
0 Pressure Variation
0.0 Pressure Variation %
0 Deflection Variation
0.0 Deflection Variation %
0 Temperatures "Keep"
0 Smoothing
0 60 Leagacy
30. No of Sequences, Drops total
5029, 4, 12, 120, 683
4 Sequences stored
12 Drops stored
120 Sequences total
683 Drops total
31. Operator Name
5030,”Operator Name“
32. Facility Information
5031,"Facility Name","Code","Type","Class"
33. Subsection Information
5032,”Section Name”,”Code”,”Start”,”End”