2017.06.19 FwdMan2.8.17.docx 19-169
19.5 Pavement Deflection Data Exchange (DDX)
This format is similar to the System.INI in Windows. The file is divided into sections each
having a bracketed header line. The data is composed of a descriptive name, an equal sign
followed by the value(s), like: Operator = John Johnson. For details see:
TUTUwww.normas.com/AASHTO/pages/PDDX.htmlUUTT.
The following shows the beginning of a DDX data file.
[Pavement Deflection Data Exchange File]
PDDXVersionNumber = 1.0
DelimiterSymbol = ,
DecimalSymbol = .
[Operations Information]
FileLocation = C:\FwdWin\Data\DBV.DDX
EndTime = 20:07:20
EndDate = 11-Dec-2001
OperatorName = ks
[Units]
LoadPlateRadiusUnits = millimetre
LoadUnits = kilo-Pascal
DeflectionUnits = micron
TemperatureUnits = Celsius
SensorsLocationUnits = millimetre
TestLocationUnits = kilometre, millimetre, millimetre
GPSUnits = degree, degree, meter
DropHistoryDataFrequencyUnits = Hertz
[Device Information]
DeviceDesignationName = Dynatest FWD
DeviceModelNumber = 8082
DeviceSerialNumber = 8082-061
LoadCellSerialNumber = 86205-0071
SensorSerialNumbers = 86211-3701,86211-3702,86211-3703,86211-3704,86211-
3705,86211-3706,86211-3707,86211-3708,86211-3709
DeviceLoadType = impulse
[Device Configuration]
LoadCellRadius = 150
NumberOfDeflectionSensors = 9
DeflectionSensorXAxisDistances = 0, 200, 300, 450, 600, 900,
1200, 1500, 1800
DeflectionSensorYAxisDistances = 0, 0, 0, 0, 0, 0,
0, 0, 0
NumberOfTemperatureSensors = 3
TemperatureSensorUse = air, surface, mid-depth
[Device Calibration]
LoadCellCalibrationFactor = 147.8
SensorDynamicCalibrationFactor = 0.977, 0.966, 0.994, 0.998, 1.022, 0.970,
0.970, 0.974, 0.983
SensorReferenceCalibrationFactor = 1.000, 1.000, 1.000, 1.000, 1.000,
1.000, 1.000, 1.000, 1.000
DMIDeviceCalibrationFactor = 60000
[Location Identification]
SiteName = Copenhagen, DK
FacilityName = Dynatest Boulevard
SectionName = East bound lane one
PavementType = ACC

Table of Contents