Error 711: Drive Controller Not Available
The Motor Controller is not available.
Possible reasons:
The Controller is not properly powered.
The FPS600 (Controller Power supply) is not properly powered.
- Check cables and connections.
- Check fuses.
- Switch off and on again after 1 minute.
- Check if Controller is ON.
- Check if FPS600 is ON.
Error 712: Drive Not Ready
The Drive has not performed the initial Homing procedure.
Possible reasons:
Batteries are low
Cable failure
Encoder mounting
Encoder failure
The Controller is not properly powered.
The FPS600 (Controller Power supply) is not properly powered.
- Check the voltage on both batteries
- Switch OFF
- Check the encoder cable and connectors
- Check the motor cable and connectors
- Make sure the screws in the motor plug are properly tied
- Check encoder mount
- Check if Controller is ON.
- Check if FPS600 is ON.
- Contact Dynatest if the error persists
Error 715: Excess Motor Controller Current
The maximum allowed current in the controller was exceeded.
Possible reasons:
Increased friction
Something is blocking the movement
The machine is tilted
- Contact Dynatest if the error persists
Error 716: Excess Motor Load
The motor is overloaded and probably too hot. This is a power protection of
the motor and/or the controller.
Possible reasons:
Too many drops in the sequence
Too short interval between sequences
Cooling problems (for water cooled systems)
- Wait 10 minutes
- Reduce the amount of mass you drop with
- Check cooling system
- Contact Dynatest if the error persists
Error 717: Excess Motor Controller Load
The motor controller is overloaded and probably too hot. This is a power
protection of the controler.
Possible reasons:
Too many drops in the sequence
Too short interval between sequences
- Wait 10 minutes to allow the motor to cool down
- Reduce the dropping mass
- Contact Dynatest if the error persists