Error 759: TG was NOT activated
The TG (Trigger) proximity switch was NOT activated when it should be.
Possible causes:
The weight WAS not resting at the base plate (of course).
TG activator trouble.
TG switch defective.
- Check the TG activator (located at weight base plate).
NOTE that the Trigger MUST be activated as long as the weight is raised
less
than 6 to 12 mm (1/4" to 1/2") !
- Check that "TG" on Computer corresponds to TG LED ON in the Trailer.
Error 760: Vehicle was NOT PARKed
The PARK (ALARM) signal obstructed the initiation of Lower Plate.
Possible causes:
You DID not Park (of course).
PARK circuit troubles.
- Check the connection to the ALARM socket at the control box (refer to
the Installation Section in the Manual).
- Check that the PRK LED at the control box light up when you park.
- Check that the PRK LED in the Trailer reflects the actual status.
Error 762: Plate Release 1 (front) Micro Switch Activated
The Micro Switch in Plate Release 1 is activated when it should not be.
Possible causes:
Electrical short
Lock malfunction
Check:
- Check Micro Switch connection, Cable, PR plug
- Check that the lock extends when the RP1 plug is disconnected
- Use button [Release Plate] to check RP1 output and Release function
Error 763: Plate Release 1 (front) Micro Switch is NOT Activated
The Micro Switch in Plate Release 1 is not activated when it should be.
Possible causes:
Electrical break
Lock malfunction
Micro Switch malfunction
Check
- Check Micro Switch connection, Cable, PR plug
- Check RP1 plug, cable, connection at solenoid
- Use button [Release Plate] to check RP1 output and Release function
Error 764: Plate Release 2 (rear) Micro Switch Activated
The Micro Switch in Plate Release 2 is activated when it should not be.
Possible causes:
Electrical short
Lock malfunction
Check:
- Check Micro Switch connection, Cable, PR plug
- Check that the lock extends when the RP2 plug is disconnected
- Use button [Release Plate] to check RP2 output and Release function
Error 765: Plate Release 2 (rear) Micro Switch is NOT Activated
The Micro Switch in Plate Release 2 is not activated when it should be.
Possible causes:
Electrical break
Lock malfunction
Micro Switch malfunction
Check
- Check Micro Switch connection, Cable, PR plug
- Check RP2 plug, cable, connection at solenoid