181
Appendix A—Parameter ID list
POWERXL SERIES VFD MN040010EN—June 2018 www.eaton.com
Menu
Item
No.
Modbus
Register
PROFIBUS EtherNet/IP DeviceNet
Parameter
Description
Data
Type
Length
(in Bytes)
Display
FormatPNU
PNU
SubIndex Class Instance Attribute Class Instance Attribute
P2.2.817917200 16016416318AI1 Sleep LimitINTEGER2x100
P2.2.918017210 16016516319AI1 Sleep DelayINTEGER2x100
P2.2.1013317120 160166163110AI1 Joystick OffsetINTEGER2x100
P2.3.12232631 160153163111AI2 Mode BYTE1x0
P2.3.2 183 260 1 160 1 58 163 1 12 AI2 Signal Range BYTE 1 x0
P2.3.31842641 160159163113AI2 Custom MinINTEGER2x100
P2.3.41852651 160160163114AI2 Custom MaxINTEGER2x100
P2.3.51822661 160161163115AI2 Filter TimeINTEGER2x100
P2.3.61892671 160167163116AI2 Signal InvertBOOLEAN1x0
P2.3.7 186 1711 1 160 1 68 163 1 17 AI2 Joystick Hyst INTEGER 2 x100
P2.3.8 187 1720 1 160 1 69 163 1 18 AI2 Sleep Limit INTEGER 2 x100
P2.3.9 188 1721 1 160 1 70 163 1 19 AI2 Sleep Delay INTEGER 2 x100
P2.3.1013417121 160171163120AI2 Joystick OffsetINTEGER2x100
P2.4.1 2484 NA NA NA NA NA NA NA NA Fine Tuning Input BYTE 1 x0
P2.4.2 2485 NA NA NA NA NA NA NA NA Fine Tuning Min INTEGER 2 x10
P2.4.3 2486 NA NA NA NA NA NA NA NA Fine Tuning Max INTEGER 2 x10
P3.1 143 425 0 160 1 169 164 1 1 IO Terminal 1 Start
Stop Logic
BYTE 1 x0
P3.2 190 414 0 160 1 72 164 1 2 IO Terminal 1 Start
Signal 1
BYTE 1 x0
P3.3 191 414 1 160 1 73 164 1 3 IO Terminal 1 Start
Signal 2
BYTE 1 x0
P3.48814090 160120016414Thermistor Input
Select
BYTE 1 x0
P3.51984212 16017416415Reverse BYTE1x0
P3.61924460 16017516416Ext. Fault 1 NOBYTE1x0
P3.71934470 16017616417Ext. Fault 1 NCBYTE1x0
P3.82004007 16017716418Fault Reset BYTE1x0
P3.9 194 400 16 160 1 78 164 1 9 Run Enable BYTE 1 x0
P3.10 205 432 0 160 1 79 164 1 10 Preset Speed B0 BYTE 1 x0
P3.11 206 432 1 160 1 80 164 1 11 Preset Speed B1 BYTE 1 x0
P3.12 207 432 2 160 1 81 164 1 12 Preset Speed B2 BYTE 1 x0
P3.1355021340 160182164113PID1 Control EnableBYTE1x0
P3.1455321341 160183164114PID2 Control EnableBYTE1x0
P3.15 195 435 0 160 1 84 164 1 15 Accel/Decel Time Set BYTE 1 x0
P3.16 201 400 5 160 1 85 164 1 16 Accel/Decel Prohibit BYTE 1 x0
P3.17 215 402 5 160 1 86 164 1 17 No Access To Param BYTE 1 x0
P3.18 203 421 4 160 1 87 164 1 18 Accel Pot Value BYTE 1 x0
P3.19 204 421 5 160 1 88 164 1 19 Decel Pot Value BYTE 1 x0
P3.20 216 405 0 160 1 89 164 1 20 Reset Pot Zero BYTE 1 x0
P3.21 196 406 0 160 1 90 164 1 21 Remote Control BYTE 1 x0
P3.22 197 406 1 160 1 91 164 1 22 Local Control BYTE 1 x0
P3.23 209 407 0 160 1 92 164 1 23 Remote 1/2 Select BYTE 1 x0
P3.24 217 417 0 160 1 93 164 1 24 Second Motor Para
Select
BYTE 1 x0
P3.25 218 NA NA 160 1 94 164 1 25 Bypass Start BYTE 1 x0
P3.26 202 402 4 160 1 95 164 1 26 DC Brake Active BYTE 1 x0
P3.27 219 402 2 160 1 96 164 1 27 Smoke Mode BYTE 1 x0
P3.28 220 402 3 160 1 97 164 1 28 Fire Mode BYTE 1 x0
P3.29 221 439 0 160 1 98 164 1 29 Fire Mode Ref 1/2
Select
BYTE 1 x0