9.4
Fault messages from the control unit DryExx
®
Advanced-ETH
Faults detected by the DryExx®-Advanced-ETH are displayed as fault
messages on the screen in plain text.
Fault description Cause Remedy
Screen output:
fault -aut. circuit breaker: digital
outputs
Overcurrent
Localise and rectify the cause of the excess
current. Switch the fuse in the switch cabinet back
on.
Short-circuit
Localise and rectify the cause of the short circuit.
Switch the fuse in the switch cabinet back on.
Screen output:
fault -aut. circuit breaker: relays
Overcurrent
Localise and rectify the cause of the excess
current. Switch the fuse in the switch cabinet back
on.
Short-circuit
Localise and rectify the cause of the short circuit.
Switch the fuse in the switch cabinet back on.
Screen output:
fault lubricant empty
Track lubricant supply
is empty
Provide new track lubricant (
Ä
Chapter
7.3.5 ‘Changing the container’ on page 50 ).
Screen output:
communication fault with partner
(releases)
Ethernet
communication is
interrupted.
Localise and rectify communication break.
The following fault can occur in all circuits (1-16), but is only described here
once as an example.
This fault message can be displayed only if the dosage rate monitoring function
is switched on (button
[ON] green).
Ä
Chapter 8.6.1.1 ‘Set the consumption management’ on page 77
Fault description Cause Remedy
Screen output:
Fault: dosing amount line 1 => check system =>
inform ECOLAB
Overdosing, e.g. due to line
break or missing spray nozzle.
Localise and replace line break
or missing spray nozzle.
Underdosing blocked line
system or nozzle.
Clean, or replace, blocked line
system or nozzle.
Dosing monitoring configured
incorrectly
Check the dosing monitoring
setting and correct if
necessary
.
Malfunctions and troubleshooting
89 Ver. 08-04.2024