Type 05010M:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard
54 l/h 159 / min
5,8 ml
185 ms
192 ms
Medium 45 l/h 145 / min 222 ms
Low 36 l/h 114 / min 333 ms
Variable
27 - 54 l/h 107 - 159 / min 370 - 185 ms
Type 12003M:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard 120 l/h 148 / min
13.5 ml
200 ms
205 ms
Medium
100 l/h 135 / min 240 ms
Low 80 l/h 106 / min 360 ms
Variable 60 - 120 l/h 99 - 148 / min 400 - 200 ms
The stroke frequency varies depending on the mode and calibration.
Functional description
33 Rev. 2-05.2018