Type 00510x:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard
5 l/h 155 / min
0,53 l/h
190 ms
197 ms
Medium 4,17 l/h 141 / min 228 ms
Low 3,33 l/h 111 / min 342 ms
Variable
2,5 - 5 l/h 104 - 155 / min 380 - 190 ms
Type 01110S:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard 11,0 l/h 176 / min
1,1 l/h
170 ms
171 ms
Medium
9,66 l/h 160 / min 204 ms
Low 7.73 l/h 126 / min 306 ms
Variable 5.8 - 11.0 l/h 117 - 176 / min 340 - 170 ms
Type 03003S:
Metering
mode Display
Metering
output
100 %
(V)
Max. stroke
frequency
at 100%
(¦)
Stroke
volume
(V
h
)
Suction
stroke
Duration
(S
t
)
min. metering
stroke
duration
(P
t
)
Standard 30 l/h 155 / min
3,4 ml
190 ms
197 ms
Medium 25 l/h 141 / min 228 ms
Low
20 l/h 111 / min 342 ms
Variable 15 - 30 l/h 104 - 155 / min 380 - 190 ms
Control / software
68Rev. 2-05.2018

Table of Contents