i
EV1000 Clinical Platform NI
Edwards Lifesciences
Operators Manual

Table of Contents

Other manuals for Edwards EV1000

Questions and Answers

  • A
    Adam LewisSep 8, 2025
    How do I fix a 'Finger Cuff #2 Error' on Edwards Medical Equipment?
    • C
      Carrie MerrittSep 8, 2025
      If you encounter a 'Fault: Finger Cuff #2 Error' on your Edwards Medical Equipment, disconnect and reconnect Edwards Cuff #2. Replace Finger Cuff #2 and restart the measurement.
  • M
    Melissa DicksonSep 7, 2025
    What to do if I get a 'Finger Cuff #1 Error' on my Edwards Medical Equipment?
    • B
      Brian ColeSep 7, 2025
      If you receive a 'Fault: Finger Cuff #1 Error' on your Edwards Medical Equipment, disconnect and reconnect Edwards Finger Cuff #1. Replace Finger Cuff #1 and restart the measurement.
  • R
    Rebecca CollinsAug 22, 2025
    What to do if I get a 'Check Blood Pressure Waveform' fault on my Edwards Medical Equipment?
    • R
      russellchristinaAug 22, 2025
      If you see a 'Check Blood Pressure Waveform' fault on your Edwards Medical Equipment, begin by assessing the system, starting from the patient, then the Finger Cuff, and finally the Pump-Unit. Check the arterial waveform for severe hypotension, severe hypertension, and motion artifact. Ensure the heart end of the Edwards HRS is aligned with the patient’s phlebostatic axis. Confirm all cable connections. Try applying the Finger Cuff to a different finger or resizing it, or replace it with a different size.
  • R
    Rebekah MartinSep 4, 2025
    How to fix 'Invalid Finger Cuff #1 Connected' fault on Edwards Medical Equipment?
    • G
      Gary GrantSep 4, 2025
      To resolve a 'Fault: Invalid Finger Cuff #1 Connected' error on your Edwards Medical Equipment, first, verify that you are using an Edwards Finger Cuff. Disconnect and reconnect Edwards Finger Cuff #1. Replace Finger Cuff #1 with a genuine Edwards Cuff and restart the measurement.
  • K
    Kevin FordSep 3, 2025
    What to do when the battery power is very low on Edwards Medical Equipment?
    • J
      James GonzalesSep 3, 2025
      If your Edwards Medical Equipment shows 'Battery power very low', connect the main power cable to charge the battery. If the system isn't connected to mains, it will shut down in one minute. When connected to mains, the battery may not charge sufficiently for battery operation, so keep the system connected to mains to charge the battery.
  • R
    Ronald RossSep 1, 2025
    What does 'Low Battery' alert mean on Edwards Medical Equipment?
    • C
      Cassandra GreerSep 1, 2025
      If you see the alert 'Low Battery' on your Edwards Medical Equipment, connect the EV1000 NI to an alternate power source to avoid loss of power and continue monitoring.
  • D
    Dr. Kurt ChapmanAug 31, 2025
    What to do if my Edwards Medical Equipment says 'Finger Cuff Disconnected'?
    • E
      Eric DunlapAug 31, 2025
      If your Edwards Medical Equipment displays 'Fault: Finger Cuff Disconnected', disconnect and reconnect the Edwards Finger Cuff(s). If the issue persists, replace the Finger Cuff(s) and restart the measurement.
  • M
    Michaela AlvaradoAug 30, 2025
    What to do if I see a 'Pump-Unit Error or Power Cable Error' on my Edwards Medical Equipment?
    • N
      Natalie TaylorAug 30, 2025
      If you encounter a 'Fault: Pump-Unit Error or Power Cable Error' on your Edwards Medical Equipment, power cycle the system. If the problem persists, replace the Pump-Unit. Power off the EV1000 Monitor, then connect the EV1000 NI Power Cable to both the Pump-Unit and the EV1000 Monitor.
  • E
    Eric MorganAug 28, 2025
    How do I troubleshoot a 'Pressure Controller Error' on Edwards Medical Equipment?
    • G
      Gregory DavidsonAug 29, 2025
      If your Edwards Medical Equipment shows a 'Pressure Controller Error', disconnect and reconnect the Edwards Pressure Controller. If that doesn't resolve the issue, try replacing the Pressure Controller.
  • E
    ehernandezAug 27, 2025
    What does 'Invalid Pump-Unit Connected' mean on Edwards Medical Equipment?
    • J
      jonathan27Aug 27, 2025
      If you see the 'Fault: Invalid Pump-Unit Connected' message on your Edwards Medical Equipment, first verify that you are using an Edwards Pump-Unit. Disconnect and reconnect the Ethernet cable. Power cycle the system and, if necessary, replace the Pump-Unit.

Summary

Chapter 1: EV1000 Clinical Platform NI Overview

ClearSight Technology Noninvasive Arterial Pressure and Cardiac Output Monitoring

Explains ClearSight technology, components, and monitoring methods.

Chapter 2: Safety and Symbols

Safety Identifying Symbols

Explains graphical identification of warnings, cautions, and notes.

Warnings

Lists and explains safety warnings relevant to the EV1000 Clinical Platform NI.

Cautions

Lists and explains safety cautions relevant to the EV1000 Clinical Platform NI.

Chapter 3: Unpacking and Initial Setup

Monitor and Pump-Unit Installation

Procedures for mounting the EV1000 monitor and pump-unit.

Initial Startup

Steps for powering on the system and initial configuration.

Chapter 4: EV1000 Clinical Platform NI Quick Start

ClearSight Technology Blood Pressure and Hemodynamic Monitoring

Overview of ClearSight monitoring, including connection and data entry steps.

Zero and Apply Heart Reference Sensor and Start Monitoring

Steps for zeroing the HRS, applying it, and initiating monitoring.

Chapter 5: Navigating the EV1000 Clinical Platform NI

Monitor Views

Overview of the seven available monitoring views.

Graphical Trend Monitoring View

Describes viewing real-time and historical trend data graphically.

Chapter 6: Monitor Display Options

Alarms; Targets

Setting and managing alarms, targets, and volumes for parameters.

Set Targets

Visual indicators for patient status relative to target ranges.

Chapter 7: Methodology and Monitoring

EV1000 Noninvasive System Methodology

Background on Volume Clamp, Physiocal, and ClearSight algorithms.

Connect the Patient Sensors

Instructions for correctly applying the Pressure Controller, HRS, and Finger Cuff.

Set Targets and Alarm Limits

Adjusting alarm limits and target values for patient parameters.

Cardiac Output Calibration

Steps for calibrating Cardiac Output (CO).

Chapter 8: Physiology and Physio Relationship Monitoring Screens

Physiology Screen

Animated display of heart, lungs, and vascular system with parameter values.

Chapter 9: Enhanced Parameter Tracking

GDT Tracking

Tools for Goal Directed Therapy (GDT) tracking and management.

Key Parameter and Target Selection

Steps to select key parameters and target ranges for GDT.

Active GDT Tracking

Describes the display of parameters within their target ranges during active tracking.

Chapter 12: Help and Troubleshooting

On Screen Help

Navigating help screens for ClearSight technology issues.

System Errors

Lists system error messages, possible causes, and suggested actions.

Numeric Keypad Errors

Troubleshooting common errors encountered with the numeric keypad.

ClearSight Faults and Alerts

Lists faults and alerts related to ClearSight Finger Cuffs and HRS.

ClearSight Warnings and Troubleshooting

Troubleshooting common warnings for ClearSight system components.

CVP Troubleshooting

Guidance for troubleshooting issues related to CVP and SVR/SVRI.

Chapter 14: EV1000 Clinical Platform NI Advanced Features

Appendix C: Monitor Settings and Defaults

Alarm and Target Defaults

Default settings for parameter alarm red zones and target ranges.

Appendix E: System Care, Service and Support

Service and Support

Information on obtaining technical support and service.

Preventive Maintenance

Recommendations for regular checks and maintenance.

Appendix F: Guidance and Manufacturers Declaration

Electromagnetic Compatibility

Information regarding EMC compliance and precautions.

Edwards EV1000 Specifications

General IconGeneral
ManufacturerEdwards Lifesciences
ModelEV1000
DisplayTouchscreen
ConnectivityEthernet
CompatibilityCompatible with Edwards Lifesciences sensors