3. Safety precautions and warnings
3.1. Operating conditions
You may use the crane ONLY if:
You are outdoors or in a space with sufficient ventilation.
The mean wind velocity is less than 10.7 m/sec (approx. 38 km/h or 24 mph). Refer to the wind
speed tables.
Operational temperature range is between -20ºC and +40ºC.
DANGER
Do not use the crane in a confined space because you could suffocate from the
exhaust gases from the vehicle.
Never use the crane in a high wind or storm. When the mean wind velocity
exceeds 10.7 m/sec (approx. 38 km/h or 24 mph), the crane will behave
unpredictably. Never use the crane during a thunderstorm.
Never use the crane at temperatures below -30°C (-22°F), as the steel's
properties deteriorate below this temperature.
WARNING
At temperatures below 0°C (32°F), do not
touch the operating levers during the first
few minutes.
In cold weather, the wear on the hydraulic
system is greater than at normal working
temperatures.
In cold weather, start the crane as follows:
Engage the power take-off at low rpm.
Allow the system to idle for a few minutes.
Operate the stabiliser legs up and down
to reach an oil temperature between 10ºC
and 15ºC. Make sure that the temperature
is between these values on the controller
display.
Safety precautions and warnings