◦ Maximum working pressure is 150 bar.
◦ Minimum distance between the nozzle and the surface to clean is 80 cm.
CAUTION
Never use a high pressure water jet on electronic parts, plastic components, signs,
bearings, control valves, cylinders or the oil tank. Only the cranes surface may be
cleaned with a high-pressure jet cleaner.
NOTE
Always lubricate after cleaning the crane.
WARNING
Keep the devices to go into the control station (handles, supports, platforms...)
clean from oil, grease and dirt to prevent slipping and falling.
8.3.1. Daily inspection
NOTE
Refer to the daily inspection checklist at the end of this manual to photocopy.
Presence of signs and symbols
• See chapter "Safety precautions and warnings" under section "Signs on the crane". Make sure
that all the signs shown in section "Signs on the crane" are in position and in good condition.
• Make sure that all the symbols on your crane are in good condition.
Locking devices
• Make sure that all locking devices are undamaged and working properly.
• Make sure that all locking devices are properly locked.
Spirit level
• Make sure that the spirit level is clearly visible to the
operator and works correctly.
Shafts, shaft locking, bearings and bushings
• Check that the shafts, shaft locking, bearings and bushings are undamaged and working
properly.
Maintenance and Service
144 EFFER 265-315-395-525 Progress 2.0 CE