NOTE
If the security seal is broken, Effer is no longer liable for any damage to
property and/or people.
4. Release the emergency stop button.
5. Make sure that all stabiliser legs are correctly set on to the ground.
6. Operate the crane only as an emergency operation to bring the crane out of the emergency
situation or to the transport position.
7.4.3. Bypass Progress (crane - stabilisers) procedure
WARNING
The use of any emergency operation is under your direct responsibility as
operator of the crane.
You must be qualified and correctly trained in the emergency operation to use
the manual commands unit. Pay careful attention when operating from the
operator station (crushing, falling, etc...) and watch out for hidden hazards (low
visibility, narrow spaces, etc...).
Always operate the crane with caution and at reduced speed.
To operate the crane like this is HIGHLY DANGEROUS because during
emergency operation all crane security is disconnected.
It is strictly forbidden to use any emergency operation as normal operation (for
example lifting a load).
Always go to/contact an authorised service workshop when a security seal has
been broken.
NOTE
Contact an authorised service workshop after using this emergency operation to
reset the system.
An acoustic signal (from the horn), repeated 3 times every 15 minutes, indicates
that the crane is working in bypass mode.
This bypass mode will be disabled as soon as the crane is switched off.