DANGER
• If a part of the crane comes in contact with
an electricity line, you will be electrocuted!
• Always keep the following minimum
distances between the crane and
overhead electricity lines, unless otherwise
prescribed by national rules.
Minimum distance between crane and overhead electricity lines
Voltage (V) Minimum distance to an insulated
conductor
Minimum distance to an uninsulated
conductor
<500 V 0.5 m 2 m
500-40000 V 1.5 m 4 m
>40000 V 2.0 m 6 m
Voltages are found:
up to 500 V: to buildings
500-40000 V: trams, trains
over 40000 V: power transmission
DANGER
When you go into the control station (high-seat, cabin, platform) remove all
jewellery, loose clothing, or other hanging items from your body (for example,
rings, scarfs, bracelets…). Jewellery, loose clothes, and other hanging items can
be caught in some parts of the crane.
DANGER
When you go into or out from the control station, use only handles and supports on
the crane that were specifically made to help the operator to go into or out from the
control station.
Safety precautions and warnings
EFFER 265-315-395-525 Progress 2.0 CE 39