20.1. BELL Output Status Monitoring
The system constantly supervises the BELL output. If the siren/bell is disconnected/cut-o, the system may send the notication by SMS
text message (by default- disabled) to the listed user phone number and indicate system fault condition on the keypad (see 29. INDI-
CATION OF SYSTEM FAULTS). Once the bell/siren is connected/xed, the system may notify the listed user by SMS text message (by
default - disabled) and the keypad will no longer indicate system fault. Please, note that in order to use this feature, the resistors must be
connected to BELL output. Resistors must be connected to BELL output to meet the monitored resistance value of 1kOhm-2.2kOhm if the
siren itself does not have this resistance (see 2.3.3. Siren).
By default, the notication by SMS text message regarding the BELL output status is disabled. To enable/disable this notication, please
refer to the following conguration methods.
Enable Siren Fail/
Restore notication
EKB2
Menu path:
User phone number: OK → iiii → OK → SMS MESSAGES 1 → OK → SIREN FAIL/REST EV → OK →
GSM USER 1... 10 → OK → ENABLE → OK
SMS text message to all users simultaneously: ... → SIREN FAIL/REST EV → OK → SMS TO ALL
→ OK → ENABLE → OK
MS delivery report: ... → SIREN FAIL/REST EV → OK → SMS REPORT → OK → ENABLE → OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number: 25 08 up 1 #
SMS text message to all users simultaneously: 21 08 1 #
SMS delivery report: 55 08 1 #
Value: up - user phone number slot, range - [01... 10].
Example: 2508021#
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
Disable Siren Fail/
Restore notication
EKB2
Menu path:
User phone number: OK → iiii → OK → SMS MESSAGES 1 → OK → SIREN FAIL/REST EV → OK →
GSM USER 1... 10 → OK → DISABLE → OK
SMS text message to all users simultaneously: ... → SIREN FAIL/REST EV → OK → SMS TO ALL
→ OK → DISABLE → OK
SMS delivery report: ... → SIREN FAIL/REST EV → OK → SMS REPORT → OK → DISABLE → OK
Value:
iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number: 25 08 up 0 #
SMS text message to all users simultaneously: 21 08 0 #
SMS delivery report: 55 08 50 #
Value: up - user phone number slot, range - [01... 10].
Example: 2508040#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
For more details on how Send SMS text message to all users simultaneously and SMS Cascade parameters aect the SMS text message
transmission, please refer to 27. SYSTEM NOTIFICATIONS.
20.2. Bell Squawk
If enabled, the siren/bell indicates the completed system arming and disarming process. After the system is successfully armed, the siren/
bell will emit 2 short beeps and 1 long beep after the system is disarmed. To enable/disable the Bell Squawk feature, please refer to the
following conguration methods. NOTE: wireless siren always emits 3 beeps regardless of arming or disarming was done.
Enable Bell Squawk
EKB2
Menu path:
OK → iiii → OK → PRIMARY SETT INGS → OK → SIREN SETTINGS → OK → BELL SQUAWK → OK
→ ENABLE → OK
Value: iiii – 4-digit installer code.