13. EXIT AND ENTRY DELAY
When arming, the system initiates the exit delay countdown (by default – 15 seconds) intended for the user to leave the secured area. The
exit delay is indicated by short beeps emitted by EKB2/EKB3/EKB3W/EWKB4 keypad buzzer and buzzer, connected to the alarm system.
When arming:
• a non-partitioned system, a countdown timer will be displayed in the home screen view of EKB2 during exit delay.
• a partitioned system, EKB2 keypad will display ARMING part-name message on the screen for 2 seconds and switch to partition
selection menu during exit delay.
Exit delay is provided when arming the system by the following methods:
• EKB2/EKB3/EKB3W/EWKB4 keypad and user/master code.
• iButton key.
• Arm/Disarm by Zone.
To arm the system without exit delay, use one of the following system arming methods:
• Free of charge phone call.
• SMS text message.
• EWK1/EWK2/EWK2A wireless keyfob
• EGR100 middle-ware.
Set exit delay
SMS
SMS text message content:
ssss_EXITDELAY:p,ext or ssss_EXITDELAY:p,ext;p,ext;p,ext;p,ext
Value: ssss – 4-digit SMS password; p – partition number, range – [1... 4], ext – exit delay
duration, range – [0... 600] seconds.
Example: 1111_EXITDELAY:1,20;3,43
EKB2
Menu path:
OK → iiii → OK → PRIMARY SETTINGS → OK → EXIT DELAY → OK → PARTITION 1... 4 → OK →
ext → OK
Value: iiii – 4-digit installer code;, ext – exit delay duration, range – [0... 600] seconds.
EKB3/
EKB3W/
EWKB4
Enter parameter 72, partition number and exit delay duration:
72 pp ext #
Value: pp – partition number, range – [01... 04], ext – exit delay duration, range – [0... 600]
seconds.
Example: 7203259#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
NOTE: Alternatively, you can set exit delay value to “0” in order to arm the system without exit delay by any available method.
NOTE: EKB3/EKB3W/EWKB4 keypad buzzer will only beep if the keypad is operating in the partition where exit delay countdown is in
progress.