8. USER PHONE NUMBERS
The system supports up to 10 user phone numbers identied as User 1 through 10. When the phone number is set, the user will be able to
arm/disarm the system by SMS text messages and free of charge phone calls (see 12.1. Free of Charge Phone Call and 12.2. SMS Text
Message) as well as to congure the system by SMS text messages. User phone numbers are also used to receive alarm phone calls via
GSM connection and SMS text messages from the system (see 17. ALARM INDICATIONS AND NOTIFICATIONS FOR USER).
By default, the system accepts incoming calls and SMS text messages from any phone number. Once a user phone number is listed, the
system ignores any incoming calls and SMS text messages from a non-listed phone number as well as it rejects the SMS text messages
containing wrong SMS password even from a listed user phone number (see 8.2. System Control from any Phone Number).
To set User 1 phone number is mandatory, while the other 9 are optional. The supported phone number formats are the following:
• International (with plus) – The phone numbers must be entered starting with plus and an international country code in the fol-
lowing format: +[international code][area code][local number], example for UK: +44170911XXXX1. This format can be used when
setting up the phone number by SMS text message and ELDES Conguration software.
• International (with 00) – The phone numbers must be entered starting with 00 and an international country code in the following
format: 00[international code][area code][local number], example for UK: 0044170911XXXX1. This format can be used when set-
ting up the phone number by SMS text message, EKB2/EKB3/EKB3W/EWKB4 keypad and ELDES Conguration software.
• Local – The phone numbers must be entered starting with an area code in the following format: [area code][local number], example
for UK: 0170911XXXX1. This format can be used when setting up the phone number by SMS text message, EKB2/ EKB3/EKB3W/
EWKB4 keypad and ELDES Conguration software.
Add user phone
number
SMS
SMS text message content:
ssss_NRup:ttteeellnnuumm
Value: ssss – 4-digit SMS password; up – user phone number slot, range – [1... 10]; ttteeelln-
nuumm – up to 15 digits user phone number.
Example: 1111_NR1:+44170911XXXX1
EKB2
Menu path:
OK → iiii → OK → PRIMARY SETTINGS → OK → CALL/SMS SETTINGS → OK → USERS → OK →
GSM USER 1... 10 → OK → PHONE NUMBER → OK → ttteeellnnuumm → OK
Value: iiii – 4-digit installer code; ttteeellnnuumm – up to 15 digits user phone number.
EKB3/
EKB3W/
EWKB4
Enter parameter 17, user phone number slot and phone number:
17 up ttteeellnnuumm #
Value: up – user phone number slot, range – [01... 10]; ttteeellnnuumm – up to 15 digits user
phone number.
Example: 17010044170911XXXX1#
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
View user phone
number
SMS
SMS text message content:
ssss_HELPNR
Value: ssss – 4-digit SMS password.
Example: 1111_HELPNR
EKB2
Menu path:
OK → iiii → OK → PRIMARY SETTINGS → OK → CALL/SMS SETTINGS → OK → USERS → OK →
GSM USER 1... 10 → OK → PHONE NUMBER
Value: iiii – 4-digit installer code;
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.