14.7. Bypassing and Activating Zones
NOTE for EKB3/EKB3W/EWKB4: The Conguration mode must remain deactivated before bypassing a violated zone or activating a by-
passed zone.
Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone. If a bypassed zone is violated
or restored during exit/entry delay, or when then system is armed, it will be ignored. When a zone is bypassed, EKB3/EKB3W/EWKB4 key-
pad indicator
will light ON and EKB2 keypad will display icon in the home screen view.
Bypass individual
violated zone
EKB2
Menu path:
OK → uumm → OK → BYPASS → OK → BYPASS LIST 1... 9 → OK → Z1-zone-name... Z80-zone-
name → OK → BYPASS → OK
Value: uumm – 4-digit user/master code; zone-name – up to 24 characters zone name.
EKB3/
EKB3W/
EWKB4
Press the key, enter zone number and user/master code:
nn uumm #
Value: nn – zone number, range – [01... 80]; uumm – 4-digit user/master code.
Example:
091111#
Bypass all violated
zones
EKB2
Menu path:
OK → uumm → OK →BYPASS → OK → BYP VIOLATED ZONES → OK
Value: uumm – 4-digit user/master code.
The zone will remain bypassed until the system is disarmed. Once the system is disarmed, the corresponding zone state will be indicated
on the keypads (see 32.1.1. EKB2 – LCD Keypad, 32.1.2. EKB3 – LED Keypad and 19.5. EKB3W/EWKB4 – Wireless LED Keypad )
and Info SMS text message (see 26. SYSTEM INFORMATION. INFO SMS). Alternatively, the user can activate the bypassed zone by the
following conguration methods.
Activate bypassed
zone
EKB2
Menu path:
OK → uumm → OK → BYPASS → OK → BYPASS LIST 1... 9 → OK → Z1-zone-name... Z80-zone-
name → OK → UNBYPASS → OK
Value: uumm – 4-digit user/master code; zone-name – up to 24 characters zone name.
EKB3/
EKB3W/
EWKB4
Press the key, enter zone number and user/master code:
nn uumm #
Value: nn – zone number, range – [01... 80]; uumm – 4-digit user/master code.
Example:
251111#
NOTE: Zones can only be bypassed and activated when the system is not armed.
14.8. Zone Names
Each zone has a name that can be customized by the user. Typically, the name species a device type connected to a determined zone
terminal, for Example: Kitchen doors opened. The zone names are used in SMS text messages that are sent to the user during alarm, the
By default, the zone names are: Z1 – Zone1, Z2 – Zone2, Z3 – Zone3, Z4 – Zone4 etc.
Set zone name
SMS
SMS text message content:
ssss_Znn:zone-name
Value: ssss – 4-digit SMS password; nn – zone number, range – [1... 80]; zone-name – up to
24 characters zone name.
Example: 1111_Z3:Door sensor triggered
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.