Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number: 25 07 up 1 #
SMS text message to all users simultaneously: 21 07 1 #
SMS delivery report: 55 07 1 #
Value: up - user phone number slot, range - [01... 10].
Example: 2107021#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
For more details on how Send SMS text message to all users simultaneously and SMS Cascade parameters aect the SMS text massage
transmission, please refer to 27. SYSTEM NOTIFICATIONS.
NOTE: In order to view the backup battery voltage, resistance, please refer to Diagnostic Management feature available on ELDES Congu-
ration software.
21.2. Mains Power Status Monitoring
If the household electricity is unstable in the system installation area, the system may temporally lose its power supply and continue oper-
ating on the backup battery power. The system supervises the mains power and noties the user by SMS text message as well as indicates
system fault condition on the keypad (see 29. INDICATION OF SYSTEM FAULTS) when the mains power is lost. When the mains power
restores, the system will notify the user by SMS text message and the keypad will no longer indicate system fault.
By default, system notication by SMS text message regarding mains power status is enabled. To disable/enable this notication, please
refer to the following conguration methods.
Disable mains
power loss/restore
notication
EKB2
Menu path:
User phone number: OK iiii OK SMS MESSAGES 1 OK MAIN POWER L/R OK
GSM USER 1... 10 OK DISBLE OK
SMS text message to all users simultaneously: ... MAIN POWER L/R OK SMS TO ALL
OK DISABLE OK
SMS delivery report: ... MAIN POWER L/R OK SMS REPORT OK DISABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number: 25 04 up 0 #
SMS text message to all users simultaneously: 21 04 0 #
SMS delivery report: 55 04 0 #
Value: up - user phone number slot, range - [01... 10].
Example: 2504050#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Enable mains
power loss/restore
notication
EKB2
Menu path:
User phone number: OK iiii OK SMS MESSAGES 1 OK MAIN POWER L/R OK
GSM USER 1... 10 OK ENABLE OK
SMS text message to all users simultaneously: ... MAIN POWER L/R OK SMS TO ALL
OK ENABLE OK
SMS delivery report: ... MAIN POWER L/R OK SMS REPORT OK ENABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number: 25 04 up 1 #
SMS text message to all users simultaneously: 21 04 1 #
SMS delivery report: 55 04 1 #
Value: up - user phone number slot, range - [01... 10].
Example: 2514091#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
By default, mains power loss and restore delay are 30 and 120 seconds respectively. To set a dierent mains power loss and restore delay