134
134
EN
ESIM384 Installation and Conguration Manual v1.1
28. EVENT AND ALARM LOG
28.1. Event Log
The event log allows to chronologically register up to 1024 timestamped records regarding the following system events:
• System start.
• System arming/disarming.
• Zone violated/restored.
• Tamper violated/restored.
• Zone bypassing.
• Wireless device management.
• Temperature deviation by MIN and MAX boundaries.
• System faults.
• Conguration via USB.
• User phone number that initiated the remote conguration.
• Communication with monitoring station status.
The event log is of FIFO (rst in, rst out) type that allows the system to automatically replace the oldest records with the latest ones.
View event log
EKB2
Menu path:
OK mmmm OK VIEW EVENT LOG OK
Value: mmmm - 4-digit master code.
To export the event log to .log le or clear it, please refer to the following conguration method.
Export/clear event log
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
By default, event log is enabled. To disable/enable this feature, please refer to the following conguration methods.
Disable event log
EKB2
Menu path:
OK iiii OK PRIMARY SETTINGS OK EVENT LOG OK DISABLE OK
Value: iiii - 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 36 and parameter status value:
36 0 #
Example: 360#
Enable event log
EKB2
Menu path:
OK iiii OK PRIMARY SETTINGS OK EVENT LOG OK ENABLE OK
Value: iiii - 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 36 and parameter status value:
36 1 #
Example:
361#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.