53
53
EN
ESIM384 Installation and Conguration Manual v1.1
12.8. Arm-Disarm by Zone
ARM/
DISARM
ZONE
The Arm-Disarm by Zone feature allows to use a zone for arming and disarming the alarm system. The process is performed by
applying a low-level pulse for more than 3 seconds to the specied zone. It means that violating and restoring the zone leads to
system arming and by repeating this action the system becomes disarmed. The system will arm/disarm the partition (-s) that
the zone is assigned to. Up to 4 on-board zones can be set to arm/disarm up to 4 system partitions by this method.
Set zone for Arm-
Disarm by Zone
method
EKB2
Menu path:
OK iiii OK ZONES OK ARM/DISARM BY ZONE OK ZONE 1... 4 OK nn
Value: iiii – 4-digit installer code; nn – on-board zone number, range – [01... 16].
EKB3/
EKB3W/
EWKB4
Enter parameter 34, on-board zone slot and zone number:
34 z nn #
Value: z – on-board zone slot for Arm-Disarm by Zone method; range - [1... 4]; nn – on-board
zone number, range – [01... 16].
Example: 34023#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Disable Arm-Disarm by
Zone method
EKB2
Menu path:
OK iiii OK ZONES OK ARM/DISARM BY ZONE OK ZONE 1... 4 OK 0
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 34, on-board zone slot and parameter status value:
34 z 00 #
Value: z – on-board zone slot for Arm-Disarm by Zone method; range - [1... 4].
Example: 34200#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
12.9. Automatic Arm/Disarm by Scheduler
The system comes equipped with an automatic arm/disarm feature that operates according to the specied weekday and time. This fea-
ture requires to set up the Start Time value of a certain scheduler and assign it to either Arm System or Disarm System action, which is
associated with a certain partition (all partitions).
Manage automatic
arm/disarm method
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
For more details on the scheduler management, please refer to 18.6.2. Schedulers.
12.10. Disabling and Enabling Arm/Disarm Notications
By default, when the system is successfully armed or disarmed, it replies with conrmation by SMS text message to:
• user phone number, sharing the same partition as EKB2/EKB3/EKB3W/EWKB4 keypad and user/master code, iButton key, EWK1/
EWK2 wireless keyfob or zone, set up for Arm/Disarm by Zone method.
• user phone number that the system arming/disarming by free of charge phone call was initiated from.
• user phone number that the system arming/disarming by SMS text message was initiated from.
The conrmation SMS text message is sent to the user phone number regarding each partition separately and contains system status and
partition name as well as it may contain a user name assigned to user phone number, user/master code or iButton key. For more details on
names, please refer to 8.1. User Phone Number Names, 10.1. User/Master Code Names and 11.2. iButton Key Names.
To disable/enable this notication for individual user phone number, please refer to the following conguration methods.
Disable arm/disarm
notication
EKB2
Menu path:
System armed:
User phone number: OK iiii OK SMS MESSAGES 1 OK SYS ARMED EVENT OK
GSM USER 1... 10 OK DISABLE OK
SMS text message to all users simultaneously: ... SYS ARMED EVENT OK SMS TO ALL
OK DISABLE OK
SMS delivery report: ... SYS ARMED EVENT OK SMS REPORT OK DISABLE OK