120
120
EN
ESIM384 Installation and Conguration Manual v1.1
26. SYSTEM INFORMATION. INFO SMS
The system supports an informational SMS text message identied as the Info SMS, which can be delivered upon request. Once
requested, the system will reply with Info SMS that provides the following:
• System date and time.
• System status: partition armed (ON)/disarmed (OFF).
• GSM signal strength.
• Mains power status.
• Temperature of the area surrounding primary and secondary temperature sensors (if any).
• State of zones (OK/alarm).
• Name and status (ON/OFF) of PGM outputs.
Request for system
information
SMS
SMS text message content:
ssss_INFO
Value: ssss – 4-digit SMS password.
Example: 1111_INFO
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
26.1. Periodic Info SMS
By default, the system sends Info SMS to User 1 phone number periodically once a day at 11:00 (frequency – 1 day; time – 11). The
minimum period is every 5 minutes, which can be set using ELDES Conguration software. Typically, this feature is used to verify the
power supply and online status of the system.
To set a dierent frequency and time or disable periodic Info SMS, please refer to the following conguration methods.
Set periodic Info SMS
frequency and time
SMS
SMS text message content:
ssss_INFO:f.it
Value: ssss – 4-digit SMS password; f – frequency, range – [0... 99] days; it – time, range
– [0... 23].
Example: 1111_INFO:3.15
EKB2
Menu path:
Frequency: OK iiii PRIMARY SETTINGS OK PERIODIC INFO OK FREQUENCY
(DAYS) f OK
Time: ... PERIODIC INFO OK TIME it OK
Value: iiii – 4-digit installer code; f – frequency, range – [00... 125] days; it – time, range –
[00... 23].
EKB3/
EKB3W/
EWKB4
Enter parameter 11, time and frequency:
11it f #
Value: it – time, range – [01... 23]; f – frequency, range – [00... 125] days.
Example: 110412#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES software.
Disable periodic Info
SMS
SMS
SMS text message content:
ssss_INFO:00.00
Value: ssss – 4-digit SMS password.
Example: 1111_INFO:00.00
EKB2
Menu path:
Frequency: OK iiii PRIMARY SETTINGS OK PERIODIC INFO OK FREQUENCY
(DAYS) 0 OK
Time: ... PERIODIC INFO OK TIME 0 OK
Value: iiii – 4-digit installer code.