ESIM384 Installation and Conguration Manual v1.1
19.4. Disabling and Enabling Siren if Wireless Signal is Lost
If a wireless device loses its wireless signal for 4-hour (by default) or longer, the system will send notication by SMS text message to user
phone number and activate the siren/bell. By default, the siren will not be activated when wireless signal is lost. To enable/disable this
feature, please refer to the following conguration methods.
Enable Siren if
Wireless Signal is Lost
EKB2
Menu path:
OK iiii OK PRIMARY SETTINGS OK SIREN SETTINGS OK SRN IF WLESS LOSS
OK ENABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 76 and parameter status value:
76 1 #
Example: 761#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Disable Siren if
Wireless Signal is Lost
EKB2
Menu path:
OK iiii OK PRIMARY SETTINGS OK SIREN SETTINGS OK SRN IF WLESS LOSS
OK DISABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 76 and parameter status value:
76 0 #
Example: 760#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
19.5. EKB3W/EWKB4 - Wireless LED Keypad
Main features:
• Alarm system arming and disarming (see 12.5. EKB3W/EWKB4 Keypad and User/Master Code).
• Arming and disarming in Stay mode (see 15. STAY MODE).
• System parameter conguration (see 5. CONFIGURATION METHODS).
• PGM output control (see 18.4. Turning PGM Outputs ON and OFF).
• Visual indication by LED indicators (see 19.5.1. LED Functionality).
• Audio indication by built-in buzzer.
• Keypad partition switch (see 23.3. Keypad Partition and Keypad Partition Switch).
For more details on technical specications and installation, please refer to the latest user manual of the device located at
www.eldesalarms.com
19.5.1. LED Functionality
INDICATION DESCRIPTION
(red)
Steady ON System armed / exit delay in progress
Flashing Conguration mode activated
(green)
Steady ON System is ready – no violated zones and/or violated tampers exist
(orange)
Steady ON System faults exist
Flashing Violated high-numbered zone
(orange)
Steady ON Violated zone bypassed
112
(red)
Steady ON Zone violated / conguration command being typed in