19.4. Disabling and Enabling Siren if Wireless Signal is Lost
If a wireless device loses its wireless signal for 4-hour (by default) or longer, the system will send notication by SMS text message to user
phone number and activate the siren/bell. By default, the siren will not be activated when wireless signal is lost. To enable/disable this
feature, please refer to the following conguration methods.
Enable Siren if
Wireless Signal is Lost
EKB2
Menu path:
OK → iiii → OK → PRIMARY SETTINGS → OK → SIREN SETTINGS →OK → SRN IF WLESS LOSS
→ OK → ENABLE → OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 76 and parameter status value:
76 1 #
Example: 761#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Disable Siren if
Wireless Signal is Lost
EKB2
Menu path:
OK → iiii → OK → PRIMARY SETTINGS → OK → SIREN SETTINGS →OK → SRN IF WLESS LOSS
→ OK → DISABLE → OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 76 and parameter status value:
76 0 #
Example: 760#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
19.5. EKB3W/EWKB4 - Wireless LED Keypad
Main features:
• Alarm system arming and disarming (see 12.5. EKB3W/EWKB4 Keypad and User/Master Code).
• Arming and disarming in Stay mode (see 15. STAY MODE).
• System parameter conguration (see 5. CONFIGURATION METHODS).
• PGM output control (see 18.4. Turning PGM Outputs ON and OFF).
• Visual indication by LED indicators (see 19.5.1. LED Functionality).
• Audio indication by built-in buzzer.
• Keypad partition switch (see 23.3. Keypad Partition and Keypad Partition Switch).
For more details on technical specications and installation, please refer to the latest user manual of the device located at
www.eldesalarms.com
19.5.1. LED Functionality
INDICATION DESCRIPTION
(red)
Steady ON System armed / exit delay in progress
Flashing Conguration mode activated
(green)
Steady ON System is ready – no violated zones and/or violated tampers exist
(orange)
Steady ON System faults exist
Flashing Violated high-numbered zone
(orange)
Steady ON Violated zone bypassed
112
(red)
Steady ON Zone violated / conguration command being typed in