EasyManua.ls Logo

Eldes ESIM384 - 9 Date and Time; Automatic Date and Time Synchronization

Eldes ESIM384
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
36
EN
ESIM384 Installation and Conguration Manual v1.1
Disable system
control from any
phone number
SMS
SMS text message content:
ssss_STR:OFF
Value: ssss – 4-digit SMS password.
Example: 1111_STR:OFF
EKB2
Menu path:
OK iiii OK PRIMARY SETTINGS OK CALL/SMS SETTINGS OK CTRL FROM ANY
NUM OK DISABLE OK
Value: iiii – 4-digit installer code;
EKB3/
EKB3W/
EWKB4
Enter parameter 12 and parameter status value:
12 0 #
Example: 120#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
9. DATE AND TIME
The system comes equipped with internal real-time clock (RTC) that keeps track of the current date and time. Once the system is up and
running, the user must set the correct date and time, otherwise the system will not operate properly. By default, after shutting down and
starting up the system, the date and time must be set again.
Set date and time
SMS
SMS text message content:
ssss_yyyy.mt.dd_hr:mn
Value: ssss – 4-digit SMS password; yyyy – year; mt – month, range – [01... 12]; dd – day, range
– [01... 31]; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59].
Example: 1111_2014.03.16_14:33
EKB2
Menu path:
a) OK uumm OK DATE/TIME SETTINGS OK yyyy-mt-dd hr:mn OK
b) OK iiii OK PRIMARY SETTINGS OK DATE/TIME SETTINGS OK yyyy-mt-dd
hr:mn OK
Value: uumm – 4-digit user/master code; yyyy – year; mt – month, range – [01... 12]; dd – day,
range – [01... 31]; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59]; iiii – 4-digit
installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 66, date and time:
66 yyyy mt dd hr mn#
Value: yyyy – year; mt – month, range – [01... 12]; dd – day, range – [01... 31]; hr – hours, range
– [00... 23]; mn – minutes, range – [00... 59].
Example: 66201405291235#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
ATTENTION! To set date and time using EKB3/EKB3W/EWKB4 command, described above, you MUST enter the Conguration mode rst!
ELDES Conguration software provides the ability to select the Time Zone option. The user may also choose Get PC Time option, which
instantly provides the exact PC time.
NOTE: When the system is connected to the monitoring station via IP connection (see 30. MONITORING STATION) and/or when ELDES
Cloud Services feature is in use (see 36. ELDES CLOUD SERVICES), the date and time will be automatically synchronized with the monitoring
station or ELDES Cloud Services server upon the system startup. However, SIA IP data format users must enable time synchronization feature
using ELDES Conguration software.
9.1. Automatic Date and Time Synchronization
This feature enables the system to set the date and time automatically without the user being involved in this process. The system sup-
ports the following methods of automatic date and time synchronization that are used automatically on system start-up and periodically
(by default – every 30 days):

Table of Contents

Related product manuals