ESIM384 Installation and Conguration Manual v1.1
17.1. Enabling and Disabling Alarm Notications
By, default the system will ring the listed user phone numbers via GSM in case of alarm. To disable/enable this feature, please refer to the
following conguration methods.
Disable call in case
of alarm
EKB2
Menu path:
OK iiii OK PRIMARY SETTINGS OK CALL/SMS SETTINGS OK CALL IN CASE
ALARM OK GSM USER 1... 10 OK DISABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 30, user phone number slot and parameter status value:
30 us 1 #
Value: us - user phone number slot, range - [01... 10].
Example: 30081#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Enable call in
case of alarm
EKB2
Menu path:
OK iiii OK PRIMARY SETTINGS OK CALL/SMS SETTINGS OK CALL IN CASE
ALARM OK GSM USER 1... 10 OK ENABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 30, user phone number slot and parameter status value:
30 us 0 #
Value: us - user phone number slot, range - [01... 10].
Example: 30090#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
By, default the system will send SMS text message to listed user phone numbers in case of alarm. To disable/enable this feature, please
refer to the following conguration methods.
Disable SMS text
message in case of
alarm
EKB2
Menu path:
User phone number: OK iiii OK SMS MESSAGES 1 OK GENERAL ALARM OK
GSM USER 1... 10 OK DISABLE OK
SMS text message to all users simultaneously: ... GENERAL ALARM OK SMS TO ALL
OK DISABLE OK
SMS delivery report: ... GENERAL ALARM OK SMS REPORT OK DISABLE OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 25/21/55, event number, user phone number slot and parameter
status value:
User phone number: 25 03 up 0 #
SMS text message to all users simultaneously: 21 03 0 #
SMS delivery report: 55 03 0 #
Value: up - user phone number slot, range - [01... 10].
Example: 2503060#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Enable SMS text
message in case of
alarm
EKB2
User phone number: OK iiii OK SMS MESSAGES 1 OK GENERAL ALARM OK
GSM USER 1... 10 OK ENABLE OK
SMS text message to all users simultaneously: ... GENERAL ALARM OK SMS TO ALL
OK ENABLE OK
SMS delivery report: ... GENERAL ALARM OK SMS REPORT OK ENABLE OK
Value: iiii – 4-digit installer code.