EasyManua.ls Logo

Eldes ESIM384 - Page 70

Eldes ESIM384
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
70
EN
ESIM384 Installation and Conguration Manual v1.1
will dial the user phone number 5 times if the rst user phone number was out of GSM signal coverage/switched OFF, otherwise the
system will dial only once. If the system ends up unsuccessful to contact any listed user phone number, will stop dialling and will not
return to the rst user phone number. The system will not dial the next listed user phone number if the previous one was available, but
rejected the phone call.
To silent the siren/bell as well as to cease system phone calls and SMS text message sending to the user phone numbers, please disarm the
system (see 12. ARMING AND DISARMING).
ATTENTION: The wireless siren EWS2/EWS3 will sound only if wireless zone of the siren is assigned to the same partition as the one that
has been alarmed (see 23.1. Zone Partition).
View violated zones
SMS
SMS text message content:
ssss_INFO
Value: ssss – 4-digit SMS password.
Example: 1111_INFO
EKB2
Menu path:
OK uumm OK VIOLATED ZONES OK ZONE 1... 80
Value: uumm – 4-digit user/master code.
EKB3/
EKB3W/
EWKB4
Please, refer to illuminated zone indicators ranging from 1 through 12 on the keypad. The
ashing indicator
represents violated high-numbered zones (Z13-Z80). For more details
on violated high-numbered zone indication, please refer to 29. INDICATION OF SYSTEM
FAULTS.
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
View violated tampers
SMS
The system will automatically send an SMS text message, containing a violated tamper name,
to user phone number.
EKB2
Menu path:
OK uumm OK VIOLATED TAMPERS OK TAMPER 1... 80
Value: uumm – 4-digit user/master code.
EKB3/
EKB3W/
EWKB4
The illuminated indicator stands for system fault presence including violated tamper. For
more details on violated tamper indication, please refer to 29. INDICATION OF SYSTEM
FAULTS.
Manage Call All in Case
of Alarm
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
For more details on how to disable/enable SMS text messages and phone calls to listed user phone number in case of alarm, please refer to
17.1. Enabling and Disabling Alarm Notications
ATTENTION: Phone calls via GSM network to the listed user phone number in case of alarm are disabled by force when MS mode is enabled
(see 30. MONITORING STATION).
NOTE: If one or more zones/tampers are violated during the alarm, the system will attempt to send as many SMS text message and dial the
user phone number as many times as the zone/tamper was violated. However, this does NOT apply to Interior Follower-type zones.
NOTE: If the system has delivered an SMS text message and/or dialled the user phone number after disarming the system, it means that the
SMS text message and/or phone call was queued up in the memory before the system was disarmed. The capacity of the queue is 24 events
maximum.
NOTE: In some case, the system might be UNABLE to dial the next listed user phone number in case the phone number has been migrated
from a dierent GSM operator.