135
135
EN
ESIM384 Installation and Conguration Manual v1.1
28.2. Alarm Log
The alarm log provides a list of last 16 alarm events generated after last arming period. The alarm log can be viewed via EKB2 and includes
only the alarms of the partition that the user/master code is assigned to. Each alarm record includes alarm type, partition number and zone
number. When highlighted, the date and time of the alarm occurrence can be viewed at the bottom of EKB2 screen. In case of alarm,
icon
will appear in home screen view of EKB2. The alarm log auto-clears when the next system arming follows or after viewing it via the keypad.
View alarm log
EKB2
Menu path:
OK uumm OK ALARM LOG OK
Value: uumm - 4-digit user/master code.
Syntax of alarm log record: [alarm-type P:p Z:nn]
Value: alarm-type - BURGLARY/FIRE/24H/SILENT/TAMPER/WS LOST, p - partition number, range - [1... 4], nn - zone/tamper number, range
- [1... 80].
#1 example of alarm log record: BURGLARY P:1 Z:1
Value: BURGLARY - Instant, Int. Follower or Delay-type zone alarm; P:1 - Partition 1; Z:1 - zone Z1.
#2 example of alarm log record: TAMPER P:2 Z:13
Value: TAMPER - tamper alarm; P:2 - Partition 2; Z:13 - tamper 13.
#3 example of alarm log record: FIRE P:4 Z:9
Value: FIRE - Fire-type zone alarm; P:4 - Partition 4; Z:9 - zone Z9.
#4 example of alarm log record: WS LOST P:2 Z:14
Value: WS LOST - wireless signal loss alarm; P:2 - Partition 2; Z:14 - tamper 14.