108
108
EN
ESIM384 Installation and Conguration Manual v1.1
duration, please refer to the following conguration methods.
Set mains power loss
delay
EKB2
Menu path:
OK iii OK PRIMARY SETT INGS OK MAIN POWER STATUS OK LOSS DELAY
OK lllll OK
Value: iiii – 4-digit installer code; lllll – mains power loss delay duration, range - [0... 65535]
seconds.
EKB3/
EKB3W/
EWKB4
Enter parameter 70 and loss delay duration:
70 lllll #
Value: lllll – mains power loss delay duration, range - [0... 65535] seconds.
Example: 7043#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Set mains power
restore delay
EKB2
Menu path:
OK iiii OK PRIMARY SETT INGS OK MAIN POWER STATUS OK RESTORE DELAY
OK rrrrr OK
Value: iiii – 4-digit installer code; rrrrr – mains power restore delay duration, range - [0...
65535] seconds.
EKB3/
EKB3W/
EWKB4
Enter parameter 71 and restore delay duration:
71 rrrrr #
Value: rrrrr – mains power restore delay duration, range - [0... 65535] seconds.
Example: 71150#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
For more details on how Send SMS text message to all users simultaneously and SMS Cascade parameters aect the SMS text message
transmission, please refer to 27. SYSTEM NOTIFICATIONS.
21.3. Memory
The conguration settings and event log records are stored in a built-in memory, therefore even if the system is fully shut down, the cong-
uration and event log remain. For more details regarding the event log, please refer to 28. EVENT AND ALARM LOG.