Disable Chime
attribute
EKB2
Menu path:
OK →iiii → OK → ZONES → OK → CHIME → OK → DISABLE → OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 32 and parameter status value:
32 0 #
Example: 320#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
Enable Chime attribute
EKB2
Menu path:
OK →iiii → OK → ZONES → OK → CHIME → OK → ENABLE → OK
Value: iiii – 4-digit installer code.
EKB3/
EKB3W/
EWKB4
Enter parameter 32 and parameter status value:
32 1 #
Example: 321#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
By default, Cross-Zone/Intelli-Zone is not set. To associate two zones and/or set the Alarm Conrmation Timeout, please refer to the fol-
lowing conguration method.
Associate a zone for
Cross-Zone/Intelli-Zone
attribute
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
Set Alarm
Conrmation Timeout
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
Set Alarm Count to
Bypass attribute for
individual zone
ELDES
Cong-
uration
soft-
ware
This operation may be carried out from the PC using the ELDES Conguration software.
ATTENTION: Cross-Zone/Intelli-Zone feature is NOT recommended in case it is necessary to bypass the associated zone, otherwise the zone
that requires alarm conrmation will never cause an alarm when violated.