EasyManua.ls Logo

Eldes ESIM384 - Page 56

Eldes ESIM384
198 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56
56
EN
ESIM384 Installation and Conguration Manual v1.1
Once the exit delay has expired, the system initiates the entry delay countdown (by default – 15 seconds) if a Delay type zone is violated.
The countdown is indicated by short beeps emitted by keypad buzzer and by steady beep emitted by system’s buzzer. The indication is in-
tended to advise the user that the system should be disarmed. Once the user presses/touches any key on the keypad during this delay, the
buzzer of the keypad will be silenced. If the system is disarmed before the entry delay expires, no alarm will be caused.
Set entry delay for
Delay zone
SMS
SMS text message content:
ssss_ENTRYDELAY:nn,eeeee or ssss_ENTRYDELAY:nn,eeeee;nn,eeeee;nn,eeeee;nn,eeeee
Value: ssss – 4-digit SMS password; nn – zone number, range – [1... 80], eeeee – entry delay
duration, range – [0... 9999] seconds.
Example: 1111_ENTRYDELAY:1,25;54,14;12,20
EKB2
Menu path:
On-board zone: OK iiii OK ZONES OK ONBOARD ZONES OK ZONE 1... 16 OK
ENTRY DELAY OK eeeee OK
Wireless zone: OK iiii OK WIRELESS ZONES OK WIRELESS ZONES 1... 4 OK
WIRELESS ZONE 13... 80 OK ENTRY DELAY OK eeeee OK
Keypad zone: OK iiii OK ZONES OK KEYPAD ZONES OK 1ST... 4TH KEYPAD
ZONE OK ENTRY DELAY OK eeeee OK
EPGM1 zone: ... EPGM1 ZONES 1-16... EPGM1 ZONES 17-32 OK EPGM1 ZONE 1... 32
OK ENTRY DELAY OK eeeee OK
Value: iiii – 4-digit installer code; eeeee – entry delay duration, range – [0... 9999] seconds.
EKB3/
EKB3W/
EWKB4
Enter parameter 54, partition number and entry delay duration:
54 nn eeeee #
Value: nn – zone number, range – [01... 80], eeeee – entry delay duration, range – [0... 9999]
seconds
Example: 5403259#
ELDES
Cong-
uration
software
This operation may be carried out from the PC using the ELDES Conguration software.
NOTE: Due to battery power saving reasons, EKB3W/EWKB4 keypad buzzer will not sound during entry delay if the violated Delay type zone
is not of the associated EKB3W/EWKB4 keypad.
For more details on zone types, please refer to 14.5. Zone Type Denitions.